{ "cells": [ { "cell_type": "markdown", "metadata": { "collapsed": true }, "source": [ "# 7.2 L, L over D and K from Kv for Conventional Type Valves" ] }, { "cell_type": "markdown", "metadata": {}, "source": [ "A 150 mm class 125 Y-pattern globe valve with a Kv=500 flow coefficient is given.\n", "\n", "Calculate the resistance coefficient K, L/D equivalent, and the length for complete turbulence in the flow.\n", "\n", "Use schedule 40, 150 mm pipe as a reference." ] }, { "cell_type": "code", "execution_count": 1, "metadata": {}, "outputs": [ { "name": "stdout", "output_type": "stream", "text": [ "Loss coefficient = 3.5996713983999995 dimensionless\n", "Equivalent length = 239.97809322666663 dimensionless\n", "Length for complete turbulence = 36.95662635690666 meter\n" ] } ], "source": [ "from fluids.units import *\n", "D = .154*u.m\n", "Kv = 500*u.m**3/u.hour\n", "\n", "K = Kv_to_K(Kv, D)\n", "L_D = L_equiv_from_K(K, fd=.015)\n", "L = D*L_D\n", "\n", "print('Loss coefficient = %s' %K)\n", "print('Equivalent length = %s' % L_D)\n", "print('Length for complete turbulence = %s' %L)" ] }, { "cell_type": "markdown", "metadata": {}, "source": [ "The results calculated in Crane TP 410M are 3.6, 240, and 37.0 respectively." ] } ], "metadata": { "language_info": { "name": "python" } }, "nbformat": 4, "nbformat_minor": 0 }